Specifications
Model number |
GSLS61 |
GSLS61-L01(Module) |
Sensing element type |
Semiconductor |
← |
Target gas |
Butane, methane |
← |
Electrical characteristics under standard Test conditions |
RH |
Heater resistance |
16Ω±0.2Ω |
PH : Less than 680 ㎽
Circuit voltage : 5V±2% |
VH |
Heater Voltage |
5.0V±2% |
RL |
Road resistance |
Variable |
PH |
Power consumption |
Less than 65 0㎽ |
VC |
Circuit Voltage |
Less than 12.0V |
Sensitivity Characteristic
β = Rs,gas/Rs,air
ΔV = Vout,air - Vout,gas |
Rs,air Vout,air |
Sensor resistance Out of Voltage |
Rs,air = 196 ㏀to 789 ㏀ |
Vout,air = 1.0V±0.2 |
β |
i-Butane
Methane
|
500ppm : 0.4±0.1
4,500ppm : 0.1±0.05
500ppm : 0.6±0.1
12,500ppm :0.25±0.05 |
At i-Butane : 4,500ppm
Methane : 12,500ppm
Vout,gas =
3.6V (Hi, variable)
Vout,air = 0V(Low)
|
ΔV |
i-Butane
Methane
|
500ppm : 0.6 ~ 1.3volt
4,500ppm : 2.1 ~ 3.2volt
500ppm : 0.3 ~ 0.7volt
12,500ppm : 1.2 ~ 1.8volt |
- |
Vout,air = 1.0Volt (In the clean air) |
Change ratio of
sensitivity α = β2/β1 |
α |
i-Butane
- 0.2 ~ 0.4
- β1 = Sensitivity at 500ppm
- β2 = Sensitivity at 4,500ppm
Methane
- 0.3 ~ 0.5
- β1 = Sensitivity at 500ppm
- β2 = Sensitivity at 12,500ppm
|
|
Response time |
Reaction : less than 10sec Recovery : less than 20sec |
Environmental
condition
|
?Standard test condition (balance gas : clean air, or special air)
?Temp. : 20°C±5°C, ?Humidity : RH65%±10%, ?Pressure : 1atm
?Test chamber : more than 1ℓ/EA, ?Pre-heating time : more than 1hr
|
Rank Table
Rank |
Resistance |
Rank |
Resistance |
Rank |
Resistance |
02A |
196 ~ 241 |
02D |
349 ~ 413 |
02G |
572 ~ 672 |
02B |
241 ~ 292 |
02E |
413 ~ 487 |
02H |
672 ~ 789 |
02C |
292 ~ 349 |
02F |
487 ~ 572 |
|
|